User's Manual

Table Of Contents
8-6 InterReach Unison Accel Installation, Operation, and Reference Manual PN 9000-10
620021-0 Rev. A
Remote Access Unit Faults
Table 8-2 Remote Access Unit Faults
Fault Message LED State Possible Causes Action Impact
Hardware failure
ALARM
Red Internal hardware failure. Replace the RAU. RAU is off-line.
Frequency band
not programmed
ALARM
Red Wrong version of RAU for
frequency band desired.
Replace the RAU if not valid
for desired frequency band.
RAU is off-line.
RAU is over
temperature
ALARM
Red Ambient temperature
above maximum.
Check environmental controls;
move the RAU to cooler envi-
ronment.
RAU is off-line.
Power supplied
by Accel Hub is
too low
ALARM
Red Cat-5/6 cable failure. Verify Cat-5/6 cable has no
shorts or opens.
RAU is off-line.
RAU internal failure.
or
Accel Hub port failure.
Move the RAU cable to another
Hub port. If fault persists,
replace the RAU; otherwise,
the Hub port is bad, mark the
port as unusable and replace the
Hub when possible.
Accel Hub internal failure. If more than one RAU con-
nected to the same Hub reports
this failure, replace the Hub.
Downlink pilot
failure
ALARM
Red Cat-5/6 cable failure. Verify that the Cat-5/6 cable
has no shorts or opens.
Verify maximum Cat-5/6 cable
length of 150 meters.
Verify minimum Cat-5/6 cable
length of 10 meters.
Degraded perfor-
mance or RAU is
off-line.
RAU internal failure.
or
Accel Hub port failure.
Move the RAU cable to another
Hub port. If fault persists,
replace the RAU; otherwise,
the Hub port is bad, mark the
port as unusable and replace the
Hub when possible.
Accel Hub internal failure. If more than one RAU con-
nected to the same Hub reports
this failure, replace the Hub.