PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 8-5
620021-0 Rev. A
RAUn over
current
and
LINK
Green Cat-5/6 cable
failure.
Verify Cat-5/6 cable has no shorts or
opens.
RAUn is
off-line.
RAU
Red
RAU internal
failure.
Move RAU to another port. If fault
persists, replace the RAU. If no fault
reported, remove the RAU, power
cycle the Hub, connect known good
RAU to port. If fault reported, replace
the Hub.
Table 8-1 Faults Reported by the Accel Hub (continued)
Fault
Message &
Icon LED State
Possible
Causes Action Impact