User's Manual
Table Of Contents
- SECTION 6 Installing Unison Accel
- 6.1 Installation Requirements
- 6.2 Safety Precautions
- 6.3 Preparing for System Installation
- 6.4 Unison Accel Installation Procedures
- 6.5 Interfacing an Accel Hub to a Base Station or a Roof-top Antenna
- 6.6 Connecting Contact Alarms to an Accel System
- 6.7 Alarm Monitoring Connectivity Options
- SECTION 7 Replacing Unison Accel Components in an Operational System
- SECTION 8 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B InterReach Unison Accel Property Sheet
- APPENDIX C Compliance
- APPENDIX D Release Notes
7-4 InterReach Unison Accel Installation, Operation, and Reference Manual PN 9000-10
620021-0 Rev. A
Replacing an Accel Hub
1. Turn off the power to the Accel Hub.
2. Disconnect all cables and the AC power cord.
3. Replace the Hub with a new one.
4. Connect the AC power cord and all cables – remembering to clean and correctly
connect the uplink and downlink cables.
5. Connect the null modem cable to the PC and then to the Hub’s front panel DB-9
serial connector.
6. Start the AdminManager software.
7. Select the Installation Wizard option from the AdminManager main window.
8. Turn on the power to the Hub.
9. Observe the LEDs after turning on the power.
If there is no band programmed in the Hub, the LEDs will blink
continuously and there is no communication with connected
Expansion Hubs or their RAUs.
If there is a band programmed, the LEDs blink for a 5-second
test. The programmed band is then issued to all Expansion Hubs
and their RAUs, and a system test is performed. It can take up to
1.5 minutes to complete the test. During System Test, the entire
system is temporarily off-line and no RF is being transmitted.
AdminManager Tasks
• Use the Installation Wizard to:
• Set the Operation Band
• Use the Configuration & Maintenance panel to:
• Set Callback Number
• Set Contact Sense Properties
• Set System Parameters
• Perform System Test
During System Test, the entire system is temporarily off-line and no RF is
being transmitted.
Always perform the system test if the band was changed.