User's Manual

Table Of Contents
PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 6-27
620021-0 Rev. A
Connecting Multiple Accel Hubs to a Duplex Repeater
or Base Station
Considerations:
2 hybrid power combiner/splitters; one for uplink and one for downlink (2x1 for
two Accel Hubs, 3x1 for three, 4x1 for four, etc.)
2 N-male to N-male coaxial jumper cables to connect each Accel Hub to the power
combiner/splitters
1 circulator
1 N-male to N-male coaxial jumper cable between each circulator and the repeater
or base station
1 N-male to N-male coaxial jumper cable1 between each circulator and power
combiner/splitter
Procedure:
1. Connect the Circulator to the power combiner/splitters and to the repeater or base
station using one N-male to N-male coaxial jumper cable.
2. Connect each power combiner/splitter to the circulator using one N-male to
N-male coaxial jumper cable.
3. Connect the power combiner/splitter to the Hubs:
a. From the first Hub’s UPLINK port to the first power combiner/splitter
b. From the first Hub’s DOWNLINK port to the second power combiner/splitter
c. From the second Hub’s UPLINK port to the first power combiner/splitter
d. From the second Hub’s DOWNLINK port to the second power combiner/splitter
4. Check Hub LEDs.
After connecting and powering on the Hub, check all LEDs to ensure that the sys-
tem is operating properly.
NOTE: Use a 50 ohm terminator on any unused power combiner/splitter ports.