6-22 InterReach Unison Accel Installation, Operation, and Reference Manual PN 9000-10
620021-0 Rev. A
Connecting a Duplex Base Station to an Accel Hub:
When connecting to a duplex base station, use a circulator between it and the Accel
Hub.
You can insert attenuators between the circulator and Hub as needed; refer to
Section 5.5.1 on page 5-43 for more information.
1. Connect an N-male to N-male coaxial cable to the duplex connector on the base
station.
2. Connect the other N-male connector to a circulator.
3. Connect an N-male to N-male coaxial cable to the DOWNLINK connector on the
Hub.
4. Connect the other end of the N-male coaxial cable to the transmit connector on the
circulator.
5. Connect an N-male to N-male coaxial cable to the UPLINK connector on the Hub.
6. Connect the other end of the N-male coaxial cable to the receive connector on the
circulator.
Figure 6-3 Duplex Base Station to an Accel Hub
N-male to N-male
Coaxial Cable
Base Station
Duplex
T1/E1 to
Mobile
Switching
Center
Insert attenuator, if needed
N-male to N-male
Coaxial Cable
Circulator