User's Manual
Table Of Contents
- SECTION 6 Installing Unison Accel
- 6.1 Installation Requirements
- 6.2 Safety Precautions
- 6.3 Preparing for System Installation
- 6.4 Unison Accel Installation Procedures
- 6.5 Interfacing an Accel Hub to a Base Station or a Roof-top Antenna
- 6.6 Connecting Contact Alarms to an Accel System
- 6.7 Alarm Monitoring Connectivity Options
- SECTION 7 Replacing Unison Accel Components in an Operational System
- SECTION 8 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B InterReach Unison Accel Property Sheet
- APPENDIX C Compliance
- APPENDIX D Release Notes
PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 5-33
620021-0 Rev. A
Narrowband Link Budget Analysis: Uplink
• e: enter the noise figure and gain of each system component (a, b, c, and d) into
the standard cascaded noise figure formula
• i = f + e + g – h
• m = j + k + l
• p = n – m – i
Therefore, the system is downlink limited but the downlink and uplink are almost
balanced, which is a desirable condition.
Line Uplink
Receiver
a. BTS noise figure (dB) 4
b. Attenuation between BTS and Unison (dB) –10
c. Unison gain (dB) 0
d. Unison noise figure (dB) 1-4-32 22
e. System noise figure (dB) 22.6
f. Thermal noise (dBm/30 kHz) –129
g. Required C/I ratio (dB) 12
h. Antenna gain (dBi) 3
i. Receive sensitivity (dBm) –97.4
Airlink
j. Multipath fade margin (dB) 6
k. Log-normal fade margin with 8 dB std. deviation, edge reliability 90%
(dB)
10
l. Body loss (dB) 3
m. Airlink losses (not including facility path loss) 19
Transmitter
n. Mobile transmit power (dBm) 28
p. Maximum path loss (dB) 106.4
F
sys
= F
1
+ + + ....
F
2
– 1
G
1
F
3
– 1
G
1
G
2
where
F = 10
(See Rappaport, Theodore S. Wireless Communications, Principles, and Practice. Prentice Hall PTR, 1996.)
(Noise Figure/10)
G = 10
(Gain/10)