PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 6-11
620021-0 Rev. A
Installing an Accel Hub in a Wall-Mounted Rack
Considerations:
The rack and the Accel Hub are both 305 mm (12 in.) deep. The rack mounting
brackets on the Accel Hub must be moved to the center mounting position to allow
for the 76 mm (3 in.) rear clearance that is required.
The maximum weight the rack can hold is 22.5 kg (50 lbs).
To install the Hub in a wall-mounted rack:
1. Attach the equipment rack to the wall using the screws that are provided.
The rack must be positioned so that the Hub will be in a horizontal position when
it is installed.
2. Remove both of the rack mounting brackets from the Hub.
3. Reattach each of the rack mounting brackets to the opposite side of the Hub from
which it came.
Refer to the following figure for bracket placement.
4. Attach the Hub to the rack.
Installing an Optional Cable Manager in the Rack
Using the screws provided, fasten the cable manager to the rack, immediately
above or below the Accel Hub.
Right Rack Mounting Bracket as
installed from the factory.
Left Rack Mounting Bracket installed on
the right side of the hub.
3''
3.5''
3''
3.5''