User's Manual

Table Of Contents
PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 6-7
620021-0 Rev. A
6.3.3 Tools and Materials Required
6.3.4 Optional Accessories
Cat-5 Extender Used if Cat-5/6 run(s) exceed 100 meters
Dual-Band Diplexer
Used in dual band systems to
combine the output of a low-band RAU and a
high-band RAU to a single
dual band antenna
Distances
Accel Hub is within 3–6m (10–20
ft) of connecting repeater
If longer distance, determine the loss of the cable used for this connection and
adjust the RF signal into the Accel Hub accordingly. This can be done by read-
justing the power from the base station, or by changing the attenuation value
between the base station/repeater and the Hub
Accel Hub is within 3–6m (10–20
ft) of connecting base station
Table 6-3 Tools and Materials Required for Component Installation
Description
Cable ties
Philips screwdriver
Mounting screws and spring nuts
Compressed air
Screws, anchors (for mounting RAUs)
Drill
Fusion splicing sleeves
Table 6-4 Optional Accessories for Component Installation
Description
Wall-mount equipment rack(s) (PN 4712)
Note that if using this rack with an Accel Hub, the Hub’s mounting bracket must be
moved to the center mounting position.
Cable management (Cable manager: PN 4759; Tie wrap bar: PN 4757)
Teltone Line Sharing Switch (M-394-B-01)
When using a single POTS line with multiple Accel Hub/Modems: Connect up to four
modems to a line sharing switch; can cascade switches to accommodate up to 16
modems per POTS line
Alarm Cables:
5-port Alarm Daisy-Chain Cable (PN 4024-3)
Alarm Sense Adapter Cable (PN 4025-1)
RAU Dust Cover (PN UNS-1RDP-1)
Table 6-2 Installation Checklist (continued)
Installation Requirement Consideration