6.1.3 Multiple Operator System Recommendations
As in any Unison Accel system, a multiple operator (neutral host) system requires
one Cat-5/6 cable between each Accel Hub and each RAU. In situations where Hubs
and/or RAUs will be installed in the future to support the addition of frequency bands
and/or wireless Operators, it is advantageous to install the necessary cabling initially.
Such deployment typically leads to substantial cost savings over installing parallel
cabling at separate times.
6.1.4 Distance Requirements
The following table shows the distances between Unison components and related
equipment.
Table 6-1 Distance Requirements
Equipment
Combination Cable Type Cable Length Additional Information
Repeater to Accel
Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum Limited by CE Mark require-
ments.
Base Station to
Accel Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum Limited by CE Mark require-
ments.
Accel Hub to RAU Cat-5/6 ScTP;
shielded RJ-45 male
connectors
Minimum: 10 meters (33 ft)
Recommended Max.: 100 meters (328 ft)
Absolute Max.: 150 meters (492 ft)
See Section 6.4.4 if using a Cat-5 Extender
See “System Gain (Loss)
Relative to ScTP Cable
Length” on page 5-28.
RAU to passive
antenna
Coaxial; SMA male
connectors
1–3.5 m (3–12 ft) typical Limited by loss and noise.
Refer to your link budget
calculation.