User's Manual

Table Of Contents
5-48 InterReach Unison Accel Installation, Operation, and Reference Manual PN 9000-10
620021-0 Rev. A
The following table shows the capacities of both 800 and 1900 MHz Unison systems
used for single and multiple protocol applications. The power per carrier for each sys-
tem is based on providing equal coverage areas for both systems when they are used
in an office building that is 80% cubicles and 20% offices.
Note 1
The RF channel capacity limits are based on the Unison data sheets’ “typical” specifications for Cat-5 length and RF performance.
Note 2
The subscriber capacity limits are based on the Erlang B traffic model with a 2% GOS. Each user has a 50mErlangs, which is higher than
the standard 35mErlangs.
Table 1
Unison Capacity: Equal Coverage Areas
Operator #1 Operator #2
Protocol
RF
Chs Voice Chs Subscribers Protocol
RF
Chs Voice Chs Subscribers
800 MHz Cellular A/B (Unison); 3 dBm power per carrier
TDMA only 35 104 1837 N/A ——
CDMA only 12 180–240 3327–4517 N/A ——
TDMA
(combining with CDMA:
Operator #2)
15 44 694 CDMA
(combining with TDMA:
Operator #1)
10 150–200 2736–3723
20 59 974 7 105–140 1856–2540
25 74 1259 4 60–80 993–1374
28 83 1431 2 30–40 439–620
800 MHz iDEN (Unison); 3 dBm power per carrier
iDEN only 16 47 749 N/A ——
1900 MHz PCS (Unison); 6 dBm power per carrier
TDMA only 14 41 638 N/A ——
CDMA only 10 150–200 2736–3723 N/A ——
GSM only 14 111 1973 N/A ——
TDMA
(combining with CDMA:
Operator #2)
617 213 CDMA
(combining with TDMA:
Operator #1)
4 60–80 993–1374
8 23 315 3 45–60 712–993
10 29 421 2 30–40 439–620
11 32 474 1 15–20 180–264
TDMA
(combining with GSM:
Operator #2)
617 213 GSM
(combining with TDMA:
Operator #1)
755 899
8 23 315 5 39 602
10 29 421 3 23 315
11 32 474 2 15 180
CDMA
(combining with GSM:
Operator #2)
2 30–40 439–620 GSM
(combining with CDMA:
Operator #1)
10 79 1355
4 60–80 993–1374 7 55 899
6 90–120 1566–2148 4 31 457
8 120–200 2148–2933 1 7 59