PRELIMINARY Fault Indications
10.2.1 Fault Indications
Once all of the units are powered on and the cable connections are made, the faults
from each unit can be requested using the AdminManager. Start with the Main Hub
and work downstream.
Resolve all faults first and then check the warnings. Take appropriate action to
resolve the faults, as indicated in the following tables. In cases where there is more
than one possible cause, they are listed from the “most likely” to the “least likely”
cause. Actions are listed in the order that they should be performed; not all actions
may need to be done.
Main Hub Faults
Table 10-1 Main Hub Faults
Fault Message LED State Possible Causes Action Impact
Hardware failure
STATUS
Red Internal hardware
failure.
Replace the Main Hub. System off-line.
Frequency band
not programmed
STATUS
Red Factory default. Program the frequency band
using the AdminManagers
Installation Wizard.
System off-line.
Main Hub is over
temperature
STATUS
Red Fan failure. If fan is not operating, replace
the Main Hub.
Possible unit failure.
Ambient tempera-
ture is above maxi-
mum.
If fan is operating, check room
environmental controls.
Failed to perform
system test
STATUS
Red Internal failure. Replace the Main Hub when
possible.
Degraded performance.