User's Manual

PN 9000-10 Help Hot Line (U.S. only): 1-800-530-9960 3-9
620021-0 Rev. A
3.4 Accel Hub Specifications
Table 3-3 Accel Hub Specifications
Specification Description
Enclosure Dimensions (H
× W × D): 133.5 mm × 438 mm × 305 mm (5.25 in. × 17.25 in. × 12 in.)
Weight < 8 kg (< 17.5 lb)
Operating Temperature 0° to +45°C (+32° to +113°F)
Non-operating Temperature –20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing 5% to 95%
External Alarm Connector
(contact closure)
1 9-pin D-sub, female
Maximum: 40 mA @ 40V DC
Typical: 4 mA @ 12V DC
Serial Interface Connector 1 RS-232 9-pin D-sub, male
RF Connectors 8 shielded RJ-45, female (Cat-5/6)
LED Fault and Status Indicators Unit Status (1 pair):
•Power
Main Hub Status
Downstream Unit/Link Status (1 pair per Cat-5/6 port):
•Link
•RAU
AC Power Rating: 115/230V, 5.5/3A, 50–60 Hz
Operating Range: 90–132V/170–250V auto-ranging,
4.6–2.3A/3.6–1.6A, 47–63 Hz
Power Consumption (W) 4 RAUs: 150 typ/178 max
4 RAUs & 4 Extenders: 167 typ/202 max
8 RAUs: 200 typ/242 max
8 RAUs & 8 Extenders: 234 typ/290 max
MTBF 78,998 hours