User's Manual

2-8 InterReach Unison Accel Installation, Operation, and Reference Manual PN 9000-10
620021-0 Rev. A
2.5 System Specifications
2.5.1 Physical Specifications
2.5.2 Environmental Specifications
Parameter Unison Accel Hub Remote Access Unit
RF Connectors 8 shielded RJ-45, female (Cat-5/6) 1 shielded RJ-45, female (Cat-5/6)
1 SMA, male (coaxial)
External Alarm Connector
(contact closure)
1 9-pin D-sub, female
Serial Interface Connector 1 RS-232 9-pin D-sub, male
LED Alarm and
Status Indicators
Unit Status (1 pair):
•Power
Status
RAU/Link Status
(1 pair per RJ-45 port):
•Link
•RAU
Unit Status (1 pair):
•Link
•Alarm
AC Power (Volts) Rating: 115/230V, 5.5/3A, 50–60 Hz
Operating Range: 90–132V/170–250V auto-ranging,
4.6–2.3A/3.6–1.6A, 47–63 Hz
DC Power (Volts) 36V (from the Hub)
Power Consumption (W) 4 RAUs: 150 typ/178 max
4 RAUs & 4 Extenders: 167 typ/202 max
8 RAUs: 200 typ/242 max
8 RAUs & 8 Extenders: 234 typ/290 max
16 max (from the Hub)
Enclosure Dimensions*
(height × width × depth)
*Excluding angle-brackets for 19'' rack mounting of hub.
Note: Unison Accel Hub typical power consumption assumes that the Cat-5/6 cable length is no more than 100 meters without a Cat-5 Extender
and no more than 170 meters with a Cat-5 Extender.
133.5 mm × 438 mm × 305 mm
(5.25 in. × 17.25 in. × 12 in.)
44 mm × 305 mm × 158 mm
(1.7 in. × 12 in. × 6.2 in.)
Weight < 8 kg (< 17.5 lb) < 1 kg (< 2 lb)
Parameter Unison Accel Hub RAU
Operating Temperature 0° to +45°C (+32° to +113°F) –25° to +45°C (–13° to +113°F)
Non-operating Temperature –20° to +85°C (–4° to +185°F) –25° to +85°C (–13° to +185°F)
Operating Humidity; non-condensing 5% to 95% 5% to 95%