User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Help Hot Line (U.S. only): 1-800-530-9960 6-7
D-620003-0-20 Rev J CONFIDENTIAL
Maximum Output Power Per Carrier at RAU
6.1.4 1800 MHz DCS
Table 6-4 DCS Power per Carrier
No. of
Carriers
Power per Carrier (dBm)
GSM
2 km SMF
GSM
1 km MMF
EDGE
2 km SMF
EDGE
1 km MMF
CDMA
2 km SMF/1 km MMF
1 17.5 17.5 17.5 17.5 16.0
2 14.5 14.0 14.5 14.0 13.0
3 12.5 12.0 12.5 12.0 11.0
4 11.5 11.0 11.5 11.0 10.0
5 10.5 10.0 10.5 10.0 9.0
6 9.5 9.0 9.5 9.0 8.0
7 9.0 8.5 9.0 8.5 7.5
8 8.5 8.0 8.0 8.0 7.0
9 8.0 7.5 7.5 7.5 6.5
10 7.5 7.5 7.0 7.0 6.0
11 7.0 7.0 6.5 6.5 5.5
12 6.5 6.5 6.0 6.0 5.0
13 6.5 6.5 6.0 6.0 5.0
14 6.0 6.0 5.5 5.5 4.5
15 5.5 5.5 5.0 5.0 4.0
16 5.5 5.5 5.0 5.0 4.0
Note: Operation at or above these output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and
EN55022 emissions requirements. Refer to the Unison Installation, Operation, and Reference manual for system design information.