User's Manual

Table Of Contents
Help Hot Line (U.S. only): 1-800-530-9960 3-9
D-620003-0-20 Rev J CONFIDENTIAL
Main Hub Specifications
3.3 Main Hub Specifications
Table 3-4 Main Hub Specifications
Specification** Description
Enclosure Dimensions (H
× W × D): 44.5 mm × 438 mm × 305 mm (1.75 in. × 17.25 in. × 12 in.)
1 U
Weight < 3 kg (< 6.5 lb)
Operating Temperature** 0° to +45°C (+32° to +113°F)
Non-operating Temperature** –20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing 5% to 95%
External Alarm Connector
(contact closure)
1 9-pin D-sub, female
Maximum: 40 mA @ 40V DC
Typical: 4 mA @ 12V DC
Serial Interface Connector 1 RS-232 9-pin D-sub, male
Fiber Connectors
4 Pair, SC/APC
a
a. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including
fiber distribution panels.
** For Japan, refer to separate addendum - Japan Specification Document.
RF Connectors 2 N-type, female
LED Fault and Status Indicators Unit Status (1 pair):
•Power
Main Hub Status
Downstream Unit/Link Status (1 pair per fiber port):
•Link
E-Hub/RAU
AC Power Rating: 100–240V, 0.5A, 50–60 Hz
Operating Range: 85–250V, 2.4–0.8A, 47–63 Hz
Power Consumption (W) 30
MTBF 106,272 hours