User's Manual

Table Of Contents
InterReach Unison Installation, Operation, and Reference Manual A-1
D-620003-0-20 Rev J CONFIDENTIAL
APPENDIX A Cables and Connectors
A.1 CAT-5E/6 Cable (ScTP)
Connects the Expansion Hub to the RAU(s)
Transmits (downlink) and receives (uplink) IF signals
Delivers DC electrical power to the RAU(s). The Expansion Hub’s DC voltage
output is 36V DC nominal. A current limiting circuit is used to protect the Expan-
sion Hub if it reaches its current limit
Carries configuration and status information
Use shielded RJ-45 connectors
Distances:
Minimum: 10 meters (33 ft)
Recommended Maximum: 100 meters (328 ft)
Absolute Maximum: 150 meters (492 ft)
Refer to Cat-5/5E/6 Cabling Requirements for Unison Family Field Note (FN04-001)
for more information.
There are four separate twisted pairs in one CAT-5E/6 screened twisted pair (ScTP)
cable. The ScTP cable loss described in this document is for CAT-5 Belden 1624P
DataTwist Five cable, or equivalent. Table A-1 lists the functional assignment of the
pairs:
Table A-1 CAT-5E/6 Twisted Pair Assignment
Pair (wire number) Function
1 & 2 Clock and Input Voltage
3 & 6 RS-485
4 & 5 Uplink IF, UL Pilot and Ground
7 & 8 Downlink IF, DL Pilot and Ground