User's Manual

Table Of Contents
Help Hot Line (U.S. only): 1-800-5 30-9960 9-3
D-620003-0-20 Rev J CONFIDENTIAL
Troubleshooting
9.3 Troubleshooting
NOTE: Unison has no user-serviceable parts. Faulty or failed units are fully
replaceable through LGC Wireless.
Sources of potential problems include:
Faulty cabling/connector
Malfunction of one or more Unison components
Antenna, base station, or repeater problem
External RF interface
Tripped circuit breaker
Using a Null modem cable that does not support full hardware handshaking when
using AdminManager
NOTE: Faulty cabling is the cause of a vast majority of problems. All
Cat-5/5E/6 cable should be tested to TIA/EIA 568-A specifications. The
RAU can be damaged if the cable is not wired correctly.
You must use AdminManager or OpsConsole for troubleshooting the system, use the
LEDs only as backup or for confirmation. However, if there are communication prob-
lems within the system, the LEDs may provide additional information that is not
available using AdminManager.
If you cannot determine the cause of a problem after following the recommended pro-
cedures, call the LGC Wireless customer help hot line:
1-800-530-9960 (U.S. only)
+1-408-952-2400 (International)
Or, email us at support@lgcwireless.com.
Please provide the following information:
Serial number of the unit
Description of the problem
Using AdminManager 2.04 or higher, execute the “Tools J Get Service Informa-
tion” command. Save and email this file to us.
What is the length of the Cat-5/5E/6 cable? Is it screened?
Status of the LEDs on the unit
Was the unit power cycled?