7.7 Connecting Contact Alarms to a Unison System
The Unison Main Hub can generate (source) two contact alarms as well as sense an
external contact alarm.
Alarm Source (refer to Section 7.7.1 on page 7-43)
The Main Hub has two alarm contacts, fault (major) and warning (minor). These
contact are normally-closed (NC) and will open when an internal alarm is detected.
NOTE: The contact can be changed to normally-open (NO) with Admin-
Manager. This is not recommended as no alarm would be sent if power to
the Main Hub fails.
Fault is activated when any faults or disconnects are detected.
Warning is activated when any warning conditions are detected except lockout
or when the end-to-end system test is not valid.
Alarm Sense (refer to Section 7.7.2 on page 7-46)
The Main Hub can monitor an external alarm contact. The port can be configured
for normally-open (NO) or normally-closed (NC) contacts. The interface expects a
set of floating contacts, and an external voltage source is not required for this inter-
face. Use AdminManager or OpsConsole to monitor the port status.
Table 7-9 lists the alarm types, equipment that Unison is connected to, cable(s) used,
and the faults (major and/or minor) that are detected.
Table 7-9 Alarm Types
NOTE: The 5-port Alarm Daisy-Chain cable is for normally closed (NC)
contacts.
Alarm
Type
Unison
connected to Cable(s) Used Alarms Detected
Source MetroReach
Focus
5-port Alarm Daisy-Chain Cable Faults
Source BTS 5-port Alarm Daisy-Chain Cable Faults and Warnings
In addition, a custom daisy-chain cable-to-BTS interface
cable is required. Make this interface cable to the desired
length and with the appropriate pin placement.
Sense LGCell 5-port Alarm Daisy-Chain Cable
and the Alarm Sense Adapter
Cable
Faults