User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- APPENDIX D Glossary
Help Hot Line (U.S. only): 1-800-5 30-9960 7-35
D-620003-0-20 Rev J CONFIDENTIAL
Interfacing a Main Hub to a Base Station or a Roof-top Antenna
7.6 Interfacing a Main Hub to a Base Station or a
Roof-top Antenna
WARNING: Only LGC personnel or LGC-authorized installation per-
sonnel should connect the Unison Main Hub to a base station or
repeater. Exceeding the maximum input power could cause failure of
the Main Hub (refer to Section 6.1 on page 6-3 for maximum power
specifications). If the maximum composite power is too high, attenua-
tion is required.
NOTE: The UPLINK and DOWNLINK ports cannot handle a DC power feed
from a base station. If DC power is present, a DC block must be used or the
main hub may be damaged.
Connecting a Main Hub to an In-Building Base Station
Connecting a Simplex Base Station to a Main Hub:
1. Connect an N-male to N-male coaxial cable to the transmit simplex connector on
the base station.
2. Connect the other end of the N-male to N-male coaxial cable to the DOWNLINK
connector on the Main Hub.
3. Connect an N-male to N-male coaxial cable to the receive simplex connector on
the base station.
4. Connect the other end of the N-male to N-male coaxial cable to the UPLINK con-
nector on the Main Hub.
Figure 7-7 Simplex Base Station to a Main Hub
N-male to N-male
Coaxial Cable
Base Station
Simplex
T1/E1 to
Mobile
Switching
Center
Insert attenuator, if needed