3.2.1 Main Hub Rear Panel Connectors
3.2.1.1 9-pin D-sub Connector
The 9-pin D-sub connector (labeled DIAGNOSTIC 1) provides contact closure for
major and minor error system alarm monitoring.
The following table lists the function of each pin on the 9-pin D-sub connector.
This interface can either generate contact alarms or sense a single external alarm con-
tact.
3.2.1.2 N-type Female Connectors
There are two N-type female connectors on the rear panel of the Main Hub:
•The
DOWNLINK connector receives downlink RF signals from a repeater, local
base station, or MetroReach Focus system.
•The
UPLINK connector transmits uplink RF signals to a repeater, local base sta-
tion, or MetroReach Focus system.
Pin Function
1 Alarm Input Ground
2 Reserved
3 Reserved
4 Warning Contact (positive connection)
5 Warning Contact (negative connection)
6 DC Ground (common)
7 Fault Contact (positive connection)
8 Alarm Input
9 Fault Contact (negative connection)