2.2.1 OA&M Software
2.2.1.1 Configuring, Maintaining, and Monitoring Unison Locally
Each Main Hub, Expansion Hub, and RAU in the system constantly monitors itself
and its downstream units for internal fault and warning conditions. The results of this
monitoring are stored in memory and compared against new results.
The Expansion Hubs monitor their RAUs and store their status in memory. The Main
Hub monitors its Expansion Hubs and stores their status and the status of the RAUs in
its memory. When a unit detects a change in status, a fault or warning is reported.
Faults are indicated locally by red status LEDs, and both faults and warnings are
reported to the Main Hub and displayed on a PC/laptop, via the Main Hub’s serial
port, that is running the AdminManager software. Passive antennas that are connected
to the RAUs are not monitored automatically. Perform the System Test in order to
retrieve status information about antennas.
Using AdminManager locally, you can install a new system or new components,
change system parameters, and query system status. The following figure illustrates
how the system reports its status to AdminManager.
Figure 2-3 Local System Monitoring and Reporting
Main
Hub
Expansion
Hub
The Main Hub checks its own status and queries each
Expansion Hub for its status, which includes RAU status.
The Expansion Hub queries its own status
and polls each RAU for its status.
Each RAU passes its status to
the Expansion Hub.
If a fault is detected, the
ALARM LED is red. If no fault
is detected, the LED is green.
If a fault or warning condition
is detected, the information is
passed to the Expansion
Hub.
The Expansion Hub queries status
of each RAU and compares it to
previously stored status.
If a fault is detected, LEDs on
the front panel turn red.
If a fault or warning condition is
detected in the Expansion Hub
or an RAU, the information is
stored in the Expansion Hub’s
memory until the Main Hub que-
ries its status.
The Main Hub queries
status of each Expansion Hub
and each RAU and compares
it to previously stored status.
If a fault is detected, LEDs
on the front panel turn red.
If a fault or warning condi-
tion is detected in any unit,
the Main Hub initiates a call
to AdminManager.
PC/Laptop
running
AdminManager
Use the Admin-
Manager to query
units for their status
or to get current
fault or warning
conditions.
RAU