User's Manual

8-6 InterReach Unison Installation, Operation, and Reference Manual PN 8700-10
620003-0 Rev. B
Checking the Main Hub’s LEDs
The LEDs should blink through a 5-second test on power up.
If the LEDs do not blink on power up, replace the Main Hub.
If the LEDs do not illuminate at all, make sure the AC power cable is con-
nected.
If the LEDs blink continuously, there is no band programmed in the Main Hub
and there is no communication with connected Expansion Hubs or their RAUs.
For each fiber optic port that has a connected Expansion Hub, which has been pro-
grammed with a band:
•The
LINK LED should be green.
•The
E-HUB/RAU LED should be green indicating that all downstream units are
functioning
Refer to Section 9.3, “Troubleshooting,” on page 9-3 for more LED states.
NOTE: If there is communication between the Main Hub and the Expansion Hubs,
use the AdminManager software’s Configuration & Maintenance panel to isolate sys-
tem problems.