7.4.1.1 Troubleshooting Main Hub LEDs During Installation
Table 7-5 Troubleshooting Main Hub LEDs During Installation
During
Installation
Power On LED State Action Impact
1. Main Hub
power is
On with
no Expan-
sion Hubs
connected.
POWER
Off Check AC power; check that the Main Hub
power-on switch is on; replace Main Hub
Main Hub is not powering
on.
LINK
LEDs on but
they didn’t
blink through
all states
Replace the Main Hub. Microcontroller not reset-
ting properly; flash memory
corrupted.
E-HUB/RAU
LINK
Red The port is unusable; replace the Main Hub
when possible.
Fiber sensor fault, do not
use the port.
E-HUB/RAU
Off
2. Main Hub
power is
On with
Expan-
sion Hubs
connected
and pow-
ered on.
LINK
Off If the port LEDs do not illuminate,
check the fiber uplink for excessive opti-
cal loss.
If Expansion Hub’s DL status LED is
red:
Verify that the fiber is connected to
the correct port (i.e., uplink/down-
link)
Swap the uplink and downlink
cables.
Connect the fiber pair to another port. If
the second port’s LEDs do not illumi-
nate Green/Red, replace the Main Hub.
If the second port works, flag the first
port as unusable; replace the Main
Hub when possible.
No uplink optical power,
Expansion Hub is not recog-
nized as being present.
No communication with the
Expansion Hub.
E-HUB/RAU
Off
LINK
Red If the Expansion Hub DL STATUS LED
is red, check the downlink fiber cable
for excessive optical loss.
Connect the fiber pair to another port. If
the second port’s LEDs do not illumi-
nate Green/Red, replace the Main Hub.
If the second port works, flag the first
port as unusable; replace the Main
Hub when possible.
No communication with the
Expansion Hub.
E-HUB/RAU
Off
LINK
Green Expansion Hub or connected RAU reports
a fault
Use AdminManager to determine the prob-
lem.
Expansion Hub or one or
more RAUs are off-line.
E-HUB/RAU
Red