User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Unison System Description
- SECTION 3 Unison Main Hub
- SECTION 4 Unison Expansion Hub
- SECTION 5 Unison Remote Access Unit
- SECTION 6 Designing a Unison Solution
- SECTION 7 Installing Unison
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Unison Component Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing a Main Hub to a Base Station or a Roof-top Antenna
- 7.7 Connecting Contact Alarms to a Unison System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Unison Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- APPENDIX B Compliance
- APPENDIX C Changes and New Capabilities
- C.1 New in Rev. M of Manual
- C.2 New in Rev. L of Manual
- C.3 New in Rev. K of Manual
- C.4 New in Rev. J of Manual
- C.5 New in Rev. H. of Manual
- C.6 New in Rev. G of Manual
- C.7 New in Rev. F of Manual
- C.8 New in Rev. E of Manual
- C.9 New in Rev. D of Manual
- C.10 New in Rev. C of Manual
- C.11 New in Rev. B of Manual
- APPENDIX D Glossary
Connecting Contact Alarms to a Unison System
7-42 InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL D-620003-0-20 Rev M
7.7 Connecting Contact Alarms to a Unison System
The Unison Main Hub can generate (source) two contact alarms as well as sense an
external contact alarm.
• Alarm Source (refer to Section 7.7.1 on page 7-43)
The Main Hub has two alarm contacts, fault (major) and warning (minor). These
contact are normally-closed (NC) and will open when an internal alarm is detected.
NOTE: The contact can be changed to normally-open (NO) with Admin-
Manager. This is not recommended as no alarm would be sent if power to
the Main Hub fails.
• Fault is activated when any faults or disconnects are detected.
• Warning is activated when any warning conditions are detected except lockout
or when the end-to-end system test is not valid.
• Alarm Sense (refer to Section 7.7.2 on page 7-46)
The Main Hub can monitor an external alarm contact. The port can be configured
for normally-open (NO) or normally-closed (NC) contacts. The interface expects a
set of floating contacts, and an external voltage source is not required for this inter-
face. Use AdminManager or OpsConsole to monitor the port status.
Table 7-9 lists the alarm types, equipment that Unison is connected to, cable(s) used,
and the faults (major and/or minor) that are detected.
Table 7-9 Alarm Types
NOTE: The 5-port Alarm Daisy-Chain cable is for normally closed (NC)
contacts.
Alarm
Type
Unison
connected to Cable(s) Used Alarms Detected
Source FlexWave
Focus
5-port Alarm Daisy-Chain Cable Faults
Source BTS 5-port Alarm Daisy-Chain Cable Faults and Warnings
In addition, a custom daisy-chain cable-to-BTS interface
cable is required. Make this interface cable to the desired
length and with the appropriate pin placement.
Sense LGCell 5-port Alarm Daisy-Chain Cable
and the Alarm Sense Adapter
Cable
Faults