Installation Manual

Appendix B: 75-Ohm CATV Cable
Page 20 InterReach Spectrum Remote Access Unit Installation Guide
© 2012 TE Connectivity Ltd TECP-77-222 • Issue 1 • August 2012
APPENDIXB:75OHMCATVCABLE
The75‐OhmCATVCable:
connectstheIFEUtoMRAU(s)andtheMRAU(s)totheSRAU(s)
transmits(FWD)mul
tibandandreceives(REV)IFsignals
de
liversDCelectricalpowertotheRAUs.TheSpectrumIFEUDCvoltageoutputis+54Vdc
nominal.IftheIFEUreachesitscurrentlimit,acurrent‐limitingcircuitprotectsit.
carriesconfigurationandstatusinformation
uses75
type‐Fconnectorswithcaptivecenterpins.
CATVCableRequirements
BeldenCATVcableorequivalentisrequired(seeFigure2).
FortheRG‐
6cable,useaBelden1695ACoax.
Forthe
RG‐11cable,useaBelden7732ACoax.
RG-11
Belden 1695A Coax
RG-6
Belden 7732A Coax
NOTE: TEConnectivityrequiressolidcoppercenterco nductorCATV cableforproperDCvoltagetothe
RAUandmaximumdist ances.
Figure2.Belden 1695A and 7732A Coax Cables
UseRG‐6orRG‐11CATVcablebetweentheIFEUandMRAU,thetypicallengthsofwhichare
listedbelow.
Cable Type
Minimum Length Maximum Length
Meters Feet Meters Feet
RG-6 0 0 140 459
RG-11 0 0 200 656