Installation Manual
Table Of Contents
Product Overview
InterReach Spectrum Remote Access Unit Installation Guide - Preliminary Update for Issue 3 Page 7
ADCP-77-168 • Issue 3 • May 2012 © 2012 TE Connectivity Ltd.
MRAU LEDs
REV IF OUT REV SECONDARY PORTS
1 2 3
FWD SECONDARY PORTS
1 2 3
FWD IF IN
LINK STATUS
41
5
2 3
Ref # LED LED Color Description
1
FWD SECONDARY PORT
(1 - 3)
2 LINK
3 STATUS
4
REV SECONDARY PORT
(1 - 3)
5 FWD IF IN
• Green • Downstream unit correctly connected; unit has no
alarms or a
Minor alarm is active.
• Blinking Green • SRAU or band is set out-of-service.
• Yellow • FWD cable connected to SRAU, no REV cable connected.
• Blinking Yellow • FWD and REV cables are not connected to the same port number
(incorrectly paired).
• Red • Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
• Off • No SRAU previously connected.
•Green •MRAU receiving communications from th
e IFEU.
• Red • MRAU has not received communications from the IFEU for more
than 90 seconds.
• Off • During initial power up, MRAU is powering up and waiting for IFEU
communications.
• Green • Unit has no alarms or a Minor
alarm is active.
• Blinking Green • Unit or band is set out-of-service.
• Red • Major alarm detected.
• Green • Downstream unit correctly connected, unit
has no alarms or minor
alarm
• Blinking Green • SRAU or band is set out-of-service.
• Blinking Yellow • FWD and REV cables are not connected to the same port number
(incorrectly paired).
• Red • Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
• Off • No SRAU previously connected.
• Green • MRAU is powered on correctly.
•Y
ellow or
Blinking Yellow
• There is an IFEU FWD connection, but there is no IFEU REV
connection or the IFEU REV connection is paired incorrectly.
• Off • Cable is not connected to the IFEU FWD port.