Installation Manual

Appendix B: 75-Ohm CATV Cable
InterReach Spectrum Remote Access Unit Installation Guide - Preliminary Update for Issue 3 Page 19
ADCP-77-168 • Issue 3 • May 2012 © 2012 TE Connectivity Ltd.
APPENDIX B: 75-OHM CATV CABLE
The 75-Ohm CATV Cable:
connects the
IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
transmits
(FWD) multiband and receives (REV) IF signals
delivers DC electrical po
wer to the RAUs. The Spectrum IFEU DC voltage output
is +54Vdc nominal. If the IFEU reaches its current limit, a current-limiting
circuit protects it.
carr
ies configuration and status information
uses 75
type-F connectors with captive center pins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
For the RG-6 cable
, use a Belden 1695A Coax.
For
the RG-11 cable, use a Belden 7732A Coax.
RG-11
Belden 1695A Coax
RG-6
Belden 7732A Coax
NOTE: ADC requires solid copper center conductor CATV cable for proper DC voltage to the RAU and
maximum distances.
Figure 2. Belden 1695A and 7732A Coax Cables
Use RG-6 or RG-11 CATV cable between the IFEU and MRAU, the typical
lengths of which are listed below.
Cable Type
Minimum Length Maximum Length
Meters Feet Meters Feet
RG-6 0 0 140 459
RG-11 0 0 200 656