Appendix B: 75-Ohm CATV Cable
InterReach Spectrum Remote Access Unit Installation Guide - Preliminary Update for Issue 3 Page 19
ADCP-77-168 • Issue 3 • May 2012 © 2012 TE Connectivity Ltd.
APPENDIX B: 75-OHM CATV CABLE
The 75-Ohm CATV Cable:
• connects the
IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
• transmits
(FWD) multiband and receives (REV) IF signals
• delivers DC electrical po
wer to the RAUs. The Spectrum IFEU DC voltage output
is +54Vdc nominal. If the IFEU reaches its current limit, a current-limiting
circuit protects it.
• carr
ies configuration and status information
• uses 75
type-F connectors with captive center pins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
• For the RG-6 cable
, use a Belden 1695A Coax.
• For
the RG-11 cable, use a Belden 7732A Coax.
RG-11
Belden 1695A Coax
RG-6
Belden 7732A Coax
NOTE: ADC requires solid copper center conductor CATV cable for proper DC voltage to the RAU and
maximum distances.
Figure 2. Belden 1695A and 7732A Coax Cables
• Use RG-6 or RG-11 CATV cable between the IFEU and MRAU, the typical
lengths of which are listed below.
Cable Type
Minimum Length Maximum Length
Meters Feet Meters Feet
RG-6 0 0 140 459
RG-11 0 0 200 656