Appendix B: 75-Ohm CATV Cable
Page 16 InterReach Spectrum Remote Access Unit Installation Guide
©
2010 ADC Telecommunications, Inc ADCP-77-168 Issue 109/2010
APPENDIX B: 75-OHM CATV CABLE
The 75-Ohm CATV Cable:
connects the IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
transmits (FWD) multiband and receives (REV) IF signals
delivers DC electrical power to the RAUs. The Spectrum IFEU DC voltage output
is 54VDC nominal. If the IFEU reaches its current limit, a current-limiting circuit
protects it.
carries configuration and status information
uses 75 type-F connectors with captive centerpins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
For the RG-6 cable, use a Belden 1695A Coax.
For the RG-11 cable, use a Belden 7732A Coax.
NOTE: ADC requires solid copper center conductor CATV cable for proper DC voltage to the RAU
and maximum distances.
Figure 2. Belden 1695A and 7732A Coax Cables
Use RG-6 or RG-11 CATV cable between the IFEU and MRAU, the typical
lengths of which are listed below.
Cable Type
Minimum Length Maximum Length
Meters Feet Meters Feet
RG-6 0 0 140 459
RG-11 0 0 200 656
RG-11
Belden 1695A Coax
RG-6
Belden 7732A Coax