User's Manual

Page 22 FlexWave Spectrum Remote Access Unit Installation Guide
©2015 TE Connectivity TECP-77-222 Issue 3 300001759666 Rev C March 2015
75-OHM CATV CABLE REQUIREMENTS AND SPECIFICATIONS
The 75-Ohm CATV Cable:
connects the IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
transmits (FWD) multiband and receives (REV) IF signals
delivers DC electrical power to the RAUs. The Spectrum IFEU DC voltage output is +54Vdc nominal. If the
IFEU reaches its current limit, a current-limiting circuit protects it.
carries configuration and status information
uses 75
type-F connectors with captive center pins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
For the RG-6 cable, use a Belden 1695A Coax.
For the RG-11 cable, use a Belden 7732A Coax.
RG-11
Belden 1695A Coax
RG-6
Belden 7732A Coax
NOTE: TE Connectivity requires solid copper center conductor CATV cable for proper DC voltage to the RAU and maximum
distances.
Figure 2. Belden 1695A and 7732A Coax Cables
Use RG-6 or RG-11 CATV cable between the IFEU and MRAU, the typical lengths of which are listed below.
Cable Type
Minimum
Length
Maximum
Length
Meters Feet Meters Feet
RG-6 0 0 125 410
RG-11 0 0 180 590