User's Manual
Table Of Contents
Low/Medium Power Level
700-900 MHz
Typical
Low/Medium Power Level
1900-2600 MHz
Typical
High
Power Level
1900-2600 MHz
Typical
3
TX RX TX RX TX RX
Average system gain with 180 m CATV
4
at 25°C (77° F) (dB) 9 to 40
1
/43
2
-1 to 30 9 to 40
1
/43
2
-1 to 30 9 to 48 -1 to 30
Ripple with 180 m CATV (dB) 2.5 3.0 3.5 4.0 3.5 4.0
Output IP3 (dBm) 38 38 43
Input IP3 (dBm) -8 -8 -8
Output 1 dB Compression Point (dBm) 26 26 31
Noise Figure 1 HU-1 EMG-8 RAUs (dB) 17 17 17
Noise Figure 1 HU-4 EMG-32 RAUs (dB) 23 23 23
1 Low Power is defined here as a Standard MRAU used with Standard SRAUs; see Table 3 on page 19.
2 Medium Power is defined here as a High Power MRAU used with Standard SRAUs; see Table 4 on page 20.
3 High Power is used to define a High Power MRAU used with High Power SRAUs; see Table 5 on page 21.
4 See “System Gain Examples” on page 18.
Page 18 FlexWave Spectrum Remote Access Unit Installation Guide
©2015 TE Connectivity TECP-77-222 Issue 3 • 300001759666 Rev C • March 2015
System Gain Examples
System Gain is the addition of the RF DART gain + the RAU gain. This section provides examples of system gain,
based on the following specifications:
1 All Standard and High Power (HP) MRAUs and SRAUs have 0 db of RX gain
2 Standard MRAU and SRAUs have 0 dB of TX gain
3 The HP MRAU adds 3 dB of TX gain on its bands and all bands of Standard and HP SRAUs connected to it
4 HP MRAUs and HP SRAUs add an additional 5 dB of TX gain on the 1900, 2100, and 2600 RF bands
Example A: All RAUs RX Configuration
RX Gain 850 MHz band: -1 to 30 dB (RF DART gain) + 0 dB (Standard MRAU and SRAU gain) = -1 to 30 dB
Example B: Low Power Level Configuration: SPT-M1-8519-1 + SPT-S2-70AWS-1-SISO
TX Gain 850 MHz band: 9 to 40 dB (RF DART gain) + 0 dB (Standard MRAU gain) = 9 to 40 dB
TX Gain 1900 MHz band: 9 to 40 dB (RF DART gain) +0 dB (Standard MRAU gain) = 9 to 40 dB
TX Gain 700 MHz band: 9 to 40 dB (RF DART gain) + 0 dB (Standard
SRAU with Standard MRAU gain) = 9 to 40 dB
TX Gain 2100 MHz band: 9 to 40 dB (RF DART gain) + 0 dB (Standard
SRAU with Standard MRAU gain) = 9 to 40
dB