User's Manual

Page 14 FlexWave Spectrum Remote Access Unit Installation Guide
©2015 TE Connectivity TECP-77-222 Issue 3 300001759666 Rev C March 2015
6 Connect F connector CATV cables on the IFEU and MRAU, in the order given below.
If the LEDs do not perform as described in this procedure, refer to “MRAU LEDs” on page 8.
a Connect
a CATV cable from one of the IFEU FWD Module IF OUT connectors (1 - 8) to the MRAU FWD IF
IN connector.
b Confirm that the MRAU FWD IF IN LED is yellow, which indicates a correct physical connection.
c Connect a CATV cable from the IFEU REV Module IF IN connector (1 - 8) to the MRAU REV IF OUT
connector, making sure that you pair the port used to the same port number selected in Step 6a.
If the connection is correct, the MRAU powers up and the MRAU FWD IF IN LED turns green.
Step 6a
IFEU
REV IF OUT REV SECONDARY PORTS
1 2 3
FWD SECONDARY PORTS
1 2 3
FWD IF IN
LINK STATUS
MRAU
To an antenna
Step 6c
KEY:
IFEU FWD Module IF OUT connector to MRAU FWD IF IN connector
IFEU REV Module IF IN connector to MRAU REV IF OUT connector
Step 6b
NOTE: Torque applied to the F connector CATV cables should be 7 ±5% in-lbs.
Connect the MRAU to SRAUs
CAUTION! To prevent interference, do not install an 850/1900 MRAU passive antenna element near an 800/900 SRAU passive
antenna element. The 850 MHz band must be ~20 feet away from the 800/1900 SRAU’s passive antenna.
7 Use one of the following 6’ and 20’ CATV RG6 jumpers, available for purchase from TE Connectivity, to
connect an MRAU to SRAUs.
TE Part Number Description Note
300469-0 6’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two cables required per SRAU.
300469-1 20’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two cables required per SRAU.