3 Connect a passive multi-band antenna to the N connector on each RAU using coaxial cable with the least
amount of loss possible. (See “Omni Antenna Specifications” on page 27 for information on the Omni Antenna
ports.)
Omni Antenna
False Ceiling
SRAU
N1
REV IF OUT REV SECONDARY PORTS
1 2 3
FWD SECONDARY PORTS
1 2 3
FWD IF IN
LINK STATUS
LINK STATUS
SECONDARY
REV
SECONDARY
FWD
MRAU
N1
Coaxial cable
Coaxial cable
CAUTION! Firmly hand-tighten the N connector. DO NOT over-tighten the connector.
Connect the IFEU to the MRAU
NOTE: The IFEU should be powered up before starting this procedure; see the InterReach Spectrum Expansion Module
Group Installation Guide (TECP-77-167).
4 Follow these rules for the CATV cables when connecting the IFEU to the MRAU:
The FWD and REV cables should be close to the same length.
The FWD and REV cables should be the same cable type (both RG6 or both RG11).
A pair of CATV cables connects each MRAU to the IFEU. The IFEU REV Module IF IN port and the IFEU
FWD Module IF OUT port must match. For example, if IFEU REV Module IF IN Port 3 is used, use IFEU
FWD Module IF OUT Port 3.
Refer
to “75-Ohm CATV Cable Requirements and Specifications” on page 22 for information on maximum
RG-6 or RG-11 CATV cable lengths.
5 Test the cable termination for each CATV cable before installing it.