Installation Instructions

Install the RAUs and Antennas
Page 16 InterReach Spectrum Remote Access Unit Installation Guide
© 2012 TE Connectivity Ltd TECP-77-222 Issue 1 November 2012
ConnecttheMRAUtoSRAUs
CAUTION! Topreventinterference,donotinstallan850/1900MRAUantennanear an800/900SRAU.The
850MHzbandmustbe20feetawayfromthe800/1900SRAU’spassiveantenna.
7 Useoneofthefollowing6’and20’CATVRG6jumpers,availableforpurchasefromTE
Connectivity,toconnectanMRAUtoSRAUs.
TE Connectivity
Part Number
Description Note
300469-0 6’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two
cables required per SRAU.
300469-1 20’ RG-6 Cable; F Male to F Male CATV cable that connects the MRAU to SRAUs. Two
cables required per SRAU.
8 TestthecableterminationforeachCATVcablebeforeinstallingit.
9 Connect
FconnectorCATVcablesfromtheMRAUtoanSRAU,intheordergivenbelow.Ifthe
LEDsdonotperformasdescribedinthisprocedure,referto“SRAULEDs”onpage10.
a Conn
ectaCATVcablefromanMRAUFWDSECONDARYPORT(1,2,or3)Fconnectorto
theSRAUSECONDARYFWDFconnector.
b ConfirmthattheSRAUSECOND
ARYFWDLEDisyellow,whichindicatesacorrect
physicalconnection.
c Conn
ectaCATVcablefromanMRAUREVSECONDARYPORT(1,2,or3)Fconnectorto
theSRAUSECONDARYREVFconnector,matchingthesameportnumberselectedinStep
9a.Thatis,ifinStep9ayouconnectedanFconnectortotheMRAUFWDSECONDARY
PORT1,thepairedCATVcablemustconnecttotheMRAUREVSECONDARYPORT1.
Iftheconnectioniscorrect,theSRAUpowersupa
ndtheSRAUSECONDARYFWDLED
turnsgreen.