Installation Instructions

Product Overview
Page 8 InterReach Spectrum Remote Access Unit Installation Guide
© 2012 TE Connectivity Ltd TECP-77-222 Issue 1 November 2012
MRAULEDs
REV IF OUT REV SECONDARY PORTS
1 2 3
FWD SECONDARY PORTS
1 2 3
FWD IF IN
LINK STATUS
415
2 3
Ref # LED LED Color Description
1
FWD SECONDARY PORT
(1 - 3)
2 LINK
3 STATUS
4
REV SECONDARY PORT
(1 - 3)
5 FWD IF IN
Green Downstream unit correctly connected;
unit has no alarms or a
Minor alarm is active.
Blinking Green SRAU or band is set out-of-service.
Yellow FWD cable connected to SRAU, no REV cable connected.
Blinking Yellow FWD and REV cables are not connected to the same port number
(incorrectly paired).
Red Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
Off No SRAU previously connected.
Green MRAU receiving communications from th
e IFEU.
Red MRAU has not received communications from the IFEU for more
than 90 seconds.
Off During initial power up, MRAU is powering up and waiting for IFEU
communications.
Green Unit has no alarms or a Minor alarm is active.
Blinking Green Unit or band is set out-of-service.
Red Major alarm detected.
Green Downstream unit correctly connected, unit
has no alarms or minor
alarm
Blinking Green SRAU or band is set out-of-service.
Blinking Yellow FWD and REV cables are not connected to the same port number
(incorrectly paired).
Red Major alarm in downstream unit, fault lockout, or SRAU
disconnected.
Off No SRAU previously connected.
Green MRAU is powered on correctly.
•Y
ellow or
Blinking Yellow
There is an IFEU FWD connection, but there is no IFEU REV
connection or the IFEU REV connection is paired incorrectly.
Off Cable is not connected to the IFEU FWD port.