User's Manual

7 / 0 7 1 0 5 1 0 5 A E
In-building Wireless Repeaters
In-building Wireless Repeaters
850 MHz Cellular and 1900 MHz PCS
2
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1
System Description
The repeater transmits RF in both directions to provide indoor wireless coverage. The device is connected
via coax to a donor antenna that is typically located on a rooftop or external wall of a building, directed
at the donor cell-site. The repeater is mounting inside the building and distributes the RF over coax to an
indoor antenna located in the desired coverage area.
Typical Installation
GUI Features
Automatic Level Control (ALC)
The system will control the output power to
maintain the stability and protect the unit.
Sleep Mode
Mode is activated when the reverse output RF
power shows below -65dBm for over 3 minutes.
The system re-activates to the wake up mode if
the signal reaches over -65dBm.
Band Selection
The BDA offers programmable band selection.
Isolation Check
There is isolation check for the forward path
and reverse path when the system is set up and
powered on.
User-friendly Interface
USB connection allows you to control;
sleep mode
band selection
on/off system controls
Over Power Shut Down
The system can detect if there is excessive
power and will shut down to protect the unit
and will automatically resume operation when
normal power levels are reached.
FPO