ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface
Page 3-6
© 2007, ADC Telecommunications, Inc.
2.2 Control Panel Information
- Gain: Show current gain of the repeater system
- Output Power: Show current output power
- System Alarm: Show current alarm status
• Isolation: When there is an error, Fwd.ShutDown, Rev.ShutDown, and Isolation signal
buttons turn red.
• PLL: When there is an error on PLL, the signal button turns red.
• Fwd.ShutDown: When output power is equal to or higher than the registered value, the
signal button turns red.
• Rev.ShutDown: When output power is equal to or higher than the registered value, the
signal button turns red.
-
Isolation Check:
“RUN” button is active. Pressing the “RUN” button starts the isolation check.
When the “Isolation Check On” check box from “Equipment Box” section is checked, the
Repeater system starts the isolation check three seconds after the BDA is connected. If you do
not press the button for three seconds the isolation check is automatically started.
If the results
produce an error, System Alarm LEDs indicate the error.
- Gain Control: Input attenuation value, to control gain of the repeater system. Press “Send”
button to apply the value to the system.
- Shut Down: Input shut down level of the repeater system. Press “Send” button to apply the
value to the system.