User's Manual
Table Of Contents
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support
- DCCS Technical Training
- Accessing FlexWave User Documentation
FlexWave
®
Prism Remote Unit and RF Module Installation Guide FWPP-504-02
Page 122 © May 2017 CommScope, Inc.
Specifications
Table 26. Notch Filter Specifications
Frequency Range (MHz) Maximum Emissions (Sprint requirement) per 30 kHz
817-824 —
< 854 < -76 dBm
854-859 < -76 dBm
859-861.35 < -76 dBm
861.35-861.5 < -56 dBm
861.5-861.6 < -42 dBm
862-869 —
Enclosure Rating
IP67
RF Connectors
N-Type Connector, Female (2)
Ground Studs (w/star washer)
All ground Studs must accept AWG 6 wire
Mounting
Strap mount (Vertical and Horizontal) on up to 12" pole, or Wall mount
Size
15.93" x 8.51" x 4.10"
Weight
18 LBS
Operational Temperature
-25°C to +65°C
Humidity
ETSI 300-019-1-3 10%-100% Condensing
Vibration-operation
ETSI 300-019-1-4
Vibration-transportation
ETSI 300-019-1-2