User's Manual
Table Of Contents
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support
- DCCS Technical Training
- Accessing FlexWave User Documentation
Specifications
FWPP-504-02 FlexWave
®
Prism Remote Unit and RF Module Installation Guide
© May 2017 CommScope, Inc. Page 121
SPECIFICATIONS
ThefollowingspecificationspertaintothePRUhardwarecomponents;forinformationonRFandoptical
specificationsandthefrequencyandcompositeoutputpowerattheAntennaport,seetheFlexWavePrism
PerformanceSpecificationsthatcorrespondtotheFlexWavesoftwarereleasemanagingthisPRU.
Table 25. Prism Remote Unit Technical Specifications
Parameter Specification Remarks
Enclosure dimensions See Table 19 on page 31
Weight See Table 18 on page 31
Mounting Wall, Pole, Inside Pole, and Vault
Outside Ambient
Temperature Rating -40° C to +50° C (-40º F to +122º F)
Storage Temperature -40° C to +70° C (-40º F to +158º F)
Humidity 10% to 90% non-condensing
Weather Resistance IP-65 Indoor or outdoor installation
Lightning Protection 20kA IEC 1000-45 8/30 ìs Waveform Provided by external lightning protector, which is an accessory.
Cooling Fan Fan, IP-55
Operating Voltage Range 10 - 28 Vdc
Connectors
Network port RJ-45 female connector
AC power connector Sealed 3-pin Connection point for the AC power cable
Antenna cable connector 50Ω N-Type (female) 50 ohms input/output impedance
Voltage input
AC-Powered PRUs 100 to 240 Vac, 50 to 60 Hz Operating range 90 to 265 Vac
DC-Powered PRUs -40 to -60 Vdc
Current rating
AC-Powered PRUs 15 AMPS
DC-Powered PRUs 45 AMPS