Prism Remote Unit and RF Module Installation Guide FWPP-504-02
Page 114 © May 2017 CommScope, Inc.
FlexWave Notch Filter (FWP-SPRINTFILTER)
FLEXWAVE NOTCH FILTER (FWP-SPRINTFILTER)
AFlexWaveNotchFilter(FWP-SPRINTFILTER)shipswithandisrequiredininstallationsofthefollowingRF
Modules:
• Dual20WSMR800/PCS1900RFModule(FWP-441T841MOD)
• Dual20W800RFModule,MIMO,SingleBay,withtwoExternalFilters(FWP-44MT000MOD).
YouinstalltheNotchFilterbetweenthePrismRemoteUnitandtheantennatoprovideprotectionfromspurious
emissionsinthePublicSafetybandbelow861.35MHzandtheCellularbandabove869.5MHz.
YouusethesamemountingmethodstomounttheNotchFilterasyouusedtomountthePRU.Takethefollowing
intoconsiderationwhenplanningtheinstallation:
• TheNotchFilteranditsmountingbracketsrequires19inchesofverticalspaceabovethePRU(seeFigure35
onpage115andFigure36onpage116).
• TheNotchFilterweighs18pounds;makesuretheinstallationsitecanbearthisadditionalweight.
• MounttheNotchFilterverticallywiththeN-typefemaleconnectorsatthebottom.
• TherearetwoGroundlugsontheNotchFilter,whichareonthebackofthetwomountingbrackets.Follow
localpracticetogroundtheNotchFilter.
• Thenotchfiltermustbeconnectedtothe800bandmoduleoutputbeforecombiningwithotherbandsor
connectingtoanantenna.