Install the RF Module(s)
CLOSE THE REMOTE UNIT DOOR AND SOLAR SHIELD
1 Donotslamthedoortocloseit—gentlyswingthedoorshutandpressitfirmlyclosed.
2 Slowlycloseeachdoorlatchinasmoothfluidmotion—donotallowthedoorlatchestosnapclosed.Forbest
results,startingwiththetoplatchandworkingdowntothebottomlatch,useaflat-headscrewdrivertoclose
eachlatchasshownbelow.
3 DonotslamtheSolarShieldtocloseit—gentlyswingitshutandpressitfirmlyclosed.
CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when
closing the Remote Unit doors after servicing.
CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be disabled for up
to three minutes. Any alarms generated immediately following the opening/closing of the PRU Doors,
such as Door Open, RF Power Low, System VSWR Fault, and LPA VSWR Fault, automatically clear once
the RF has recovered. If alarms do not clear after three minutes, please contact CommScope for
technical support; see "DCCSGlobalTechnicalSupport”onpage124.
Solar Shield Door
Door latch