User's Manual

Install the RF Module(s)
FWPP-504-02 FlexWave
®
Prism Remote Unit and RF Module Installation Guide
© May 2017 CommScope, Inc. Page 111
3 FollowtheruleslistedbelowtotogglethePowerswitchthatcorrespondstoeachRFModuletoitsON
position.
ForDual-BandDual-BayRFModules,usethePowerswitchforthelowermodule.Forexample,topower
upaDual-BayRFModuleincombinedbaysC+DinaQuad-Baychassis,turnONDCPowerswitchforMod
C;leavetheDCPowerswitchforModDOFF.
ALegacyDual-Bay40WRFModuleusesthePowerSuppliesinbothbays.IftheLegacyDual-Bay40WRF
ModuleisinstalledinbaysC+D,turnONthePowerswitchforModCandModD.
4 VerifythattheLEDsforallinstalledRFModules(locatednexttotheirrespectiveconnectors)aregreen.Ifany
oftheRFModuleLEDsarenotgreen,verifythateachRFModulecableisseatedfullyinitsrespective
connector.IfaftercheckingthecableconnectionsandanLEDisnotgreen,contactCommScopeforassistance
(see
"DCCSGlobalTechnicalSupport”onpage124).
ForfurtherinformationonStatusLEDsonHDMRFModules,see"LEDSonNarrowbandHDMRFModules”on
page21and"LEDSonWidebandandFullbandHDMRFModules”onpage22.
Bay A
SeRF Module
AC/DC Power
switch for
PRU chassis
DC Power switch for Bay A
DC Power switch for Bay B
DC Power switch for Bay C
DC Power switch for Bay D
Bay B
Bay C
Bay D