FlexWave
®
Prism Remote Unit and RF Module Installation Guide FWPP-504-02
Page 94 © May 2017 CommScope, Inc.
Install the RF Module(s)
3 AligntheMountingHookonthemodulewiththereceivingflangeonthePRUheatsink,andthenslidetheRF
Moduleintowardtheflangeuntilitcangonofurther.
4 PushtheleftedgeoftheRFModulebackandintothePRUchassisuntilitcangonofurther,asshowninthe
followinggraphics:
• ForSingle-BayRFModules,seeFigure25onpage95.
• ForHDMRFModules,seeFigure26onpage96.
• ForDual-BayRFModules,seeFigure27onpage97,whichusestheLegacyDual-Bay40WRFModuleas
anexample.
CAUTION! Make sure the RF Module is seated correctly in the Module shelf. Incorrect alignment of the RF Module
can cause the RF Module to fail due to overheating.
• The front edge of the RF Module should be parallel with the shelf above it.
• The Mounting Hook on the RF Module should be fully engaged with the Receiving flange on the
Remote Unit chassis.
• An incorrectly seated RF Module makes closing the Prism door difficult. If you later cannot shut the
Remote Unit door, verify that the RF Module is installed correctly.
RF Module
Mounng
hook
Chassis
Receiving
flange
Mounng Bracket at
back of the PRU
(View is looking down into the
PRU chassis from the top.)