User's Manual

Overview of Prism Remote Units
FWPP-504-02 FlexWave
®
Prism Remote Unit and RF Module Installation Guide
© May 2017 CommScope, Inc. Page 11
SeRF Module LEDs
NOTE: The SeRF Module LEDs automatically enter a LED Roll Test sequence (cycle through its colors) when the
SeRF FPGA is loaded (approximately 4 minutes after initial power up) or when a SeRF synthesizer failure
occurs. The LED Roll Test sequence takes approximately two seconds to complete, and cycles the
ALARM, SYNTH, and STATUS LEDs, after which the LEDs begin normal operation. Additionally, an active
SeRF Synthesizer failure causes the same LED sequencing approximately every minute until the SeRF
failure clears.
LED LED Color Description
POWER
•GREEN •Power OK and operating properly
RED Power supply out of tolerance
•OFF •No power present
STATUS
GREEN
•RED
No alarm for the SeRF II Module
Initial bootup sequence and should become GREEN within 1 minute;
if RED after bootup, a Major alarm exists for the SeRF Module
SYNTH
•GREEN •Locked
RED Unlocked or is in initial bootup sequence
ALARM
•GREEN •No major alarm is present in the PRU or in any downstream unit
RED Initial bootup sequence, or a major alarm is present in the PRU or in any downstream unit
SeRF Module
POWER
STATUS
SYNTH
ALARM