User's Manual

FlexWave
®
Prism Remote Unit and RF Module Installation Guide FWPP-504-02
Page 66 © May 2017 CommScope, Inc.
Install the Prism Remote Unit
7 AttachthestrengthmemberfromtheFiberOpticcabletotheStrain-Relieflugontheinsidebottomofthe
PRU.
8 Tightenth
eexternaldomenutofthePass-ThroughConnectoraroundtheFiberOpticcable—torquethe
domenutto44in-lbsplusorminus4in-lbs.
9 Route
thefibercablefromtheundersideofthePRUtotheOSPbox.
10 Followl
ocalpracticestosecurethefibercableinplace.
11 (O
ptional)OneSFPsupportsupto12timeslotswith75MHzofbandwidth.Ifasecondfibercableassembly
isrequired(forexample,yourPrismsystemhasthreeSFPstohandleupto280MHzofRFbandwidth),
completeStep3onpage63throughStep10onpage66toaddthesecondfibercableassembly,onlythistime,
connecttotheFiber2connectorlo
catedatthebottomofthePRUasshowninStep4onpage64.
12 Returntot
hemaininstallationprocessandcontinueat"ConnecttheAntennaCable”onpage71.
Strain-relief lug