User's Manual
Table Of Contents
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Determine the Circuit Breaker or Fuse for the PRU
- Connect the Power Wiring
- (Optional) Connect the Prism Remote Unit to a UPS
Install the Prism Remote Unit
FWPP-504-02 FlexWave
®
Prism Remote Unit and RF Module Installation Guide
© May 2017 CommScope, Inc. Page 31
Figure9onpage32throughFigure12onpage35providethespacingdimensionsforbandsandbracket
mountingbolts.
Table 18. Prism Remote Unit Weights
(1)
PRU Model Unpopulated Populated
Single-Bay
Pounds
Kilograms
65 83
29 38
Dual-Bay
Pounds
Kilograms
81 117
37 53
Tri-Bay
Pounds
Kilograms
97 151
44 68
Quad-Bay
Pounds
Kilograms
116 188
53 85
1 Unpopulated” weight includes the SeRF Module and
the Solar shields, which are always present.
“Populated” weight is the weight of the chassis that
has the SeRF Module and RF Modules installed.
Table 19. Prism Remote Unit Enclosure Dimensions
(1)
PRU Model Height Width
(2)
Depth See…
Single-Bay
Inches
Centimeters
25.2 12.2 11.2
64 30.99 28.45
Figure 9 on page 32
Dual-Bay
Inches
Centimeters
33.2 12.2 11.2
84.3 30.99 28.45
Figure 10 on page 33
Tri-Bay
Inches
Centimeters
41.2 12.2 11.2
104.6 30.99 28.45
Figure 11 on page 34
Quad-Bay
Inches
Centimeters
52.4 12.2 11.2
133.10 30.99 28.45
Figure 12 on page 35
1 To have adequate clearance to open the PRU chassis door, allow a minimum of 18 inches at
the left, right and front of each PRU.
2 Dimension for width includes the mounting brackets.