Connect the RF Module Cables
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 37
TECP-77-141 • Issue 1 • April 2012 © 2012 TE Connectivity Ltd.
13 Workingfromthebottomconnectorup,connecttheRFModulecables.
a IfthisisaDiversitychassis:
• ForSingle‐Slotinstallationsonly—connecttheRFDiversitycablelabeledMODN
TX1/RX1
totheTX1/RX1connectorandturnthethumbscrewtosecurethecabletothe
chassis.
• ForDual‐Slotinstallationsonly—theTX1/RX1connectorispre‐populated.Donot
removethefactoryconnectiontoRX1.Instead,securethe
MODNTX1/RX1cabletothe
cablebundleusingoneoftheprovidedcableties.Ensurethatthe
MODNTX1/ RX1cable
andconnectoraresecuredsotheywillnotbepinchedorpreventthedoorfrom
closing.
b ConnecttheRFcablelabeledMODNTX0/RX0totheTX0/RX0connectorandturnthe
thumbscrewtosecurethecabletothechassis.
c ForSingle‐Slotinstallationsonly—connecttheMODNDIV LVDScabletotheDIV
connector.ThisconnectstheRemoteUnitSeRF(RSI)interfaceboardtotheDiversity
DART.MakesurethatyouheartheLVDScablelockintotheDIVconnectorwithanaudible
click.GiveagentletugontheLVDScable—ifyoudonotpresstheunlocklever,theLVDS
cableshouldnotcomeoutoftheconnector.
NOTE: AlwaysconnecttheDiversityLVDScable.Thispreventsthecablefromgettingcaughtbetween
thechassisdoorandtheRFModule.
d ConnecttheMODNPRIMLVDScabletothePRIMconnector.ThisconnectstheRSItothe
PrimaryDART.
e ConnectthePowercabletothePWRconnector.ThisconnectstheRFModuletotheDC
powerconnection.
f ForDual‐Slotinstallationsonly—thePower(PWR)cableandtwoLVDScablesofthe
upperRFModuleshelfarenotbeused.ConnecttheRFcablelabeled
MODN TX1/RX1ofthe
upperRFModuleshelftotheconnectorlabeled
N/ContheupperhalfoftheDual‐Slot
module.Useoneoftheprovidedcabletiestosecurethe
MODNTX0/RX0RFcable,both
LVDScablesandthePower(PWR)cabletotheRFcablelabeled
MODNTX1/RX1,ensuring
thatthecablebundlewillnotbepinchedorpreventthePRUdoorfromclosing.
RefertothegraphicthatcorrespondstotheRFModulebeinginstalled:
• Single‐SlotRFModule:Figure21onPage38
• HDMRFModule:Figure22onpage39
• Dual‐BandDual‐SlotRFModule:Figure23onPage40
• Dual‐Slot40WRFModule:Figure24onPage41.