Install the RF Module(s)
Page 24 FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2012 TE Connectivity Ltd TECP-77-141 • Issue 1 • April 2012
InstalltheRFModuleintothePrismRemoteChassis
Recommendation: InstallDual‐BandDual‐Slotmodulesinthetwoupper‐mostslotsofthePRU.
Recommendation: InstallDual‐Slot40Wmodulesinthebottom‐mostslotsofthePRU.
Recommendation: IfbothaDual‐SlotAWS210040WRFModuleandaDual‐SlotPCS190040W
RFModuleareinstalledinaQuad‐BandPRU,installtheAWS2100Modulein
thelower‐mostslotofthePRU.
5 HoldtheRFModulesothattheDARTcard(s)faceawayfromthePRUandtheMountingHook
istowardtheReceivingflangeonthePRUchassis.
NOTE: AlwaysinstallRFModulesfromthebottomup.Donotskipaslot.
6 HoldingtheRFModuleata45°angleinrespecttotherearheatsink,restthebottomsurface
ofthemoduleontheRFModuleshelf,asshowninoneofthefollowinggraphics,andas
applicabletotheRFModule.
• Single‐SlotRFModule:Figure11onpage25
• HDMRFModule:Figure12onpage26
• Dual‐BandDual‐SlotRFModule:Figure13onPage27
• Dual‐Slot40WRFModule:Figure14onPage28.