Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- Understanding the RF Module Cables
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables
- Power on the RF Module
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page6 FlexWavePrismRemoteUnitRFModuleInstallationGuide
©2014 TEConnectivityLtd. TECP‐77‐141Issue6 • 300001744178RevF • April2014
RFModuleDARTs
EachRFModulecansupportanyofthefollowingDARTcombinations:
• oneClassic
DARToroneSingleSuperDART
• twoClassicDARTs(i.e.,t
he6.5W800/900ESMRModule,Non‐Diversity,Classic)
• twoClassicDARTs—Diversi
ty
• twoSingleSuperDARTs—Diversity
• on
eDualSuperDART
• on
eortwosetsofTxorRxBoards(HDM).
EachRFModulewillhaveuptotwo6‐timeslotDARTsorone12‐times
lotDARTperRFModule.
TheDARTtypedeterminesthemaximumnumberoflinks,wherether
ecanbeuptoeightClassicDARTsorSingle
SuperDARTsthatsupport39MHzeach,orupto4DualSuperDARTsthatsupportupto75MHzeach.
PrismsupportstheDARTModuletypeslistedbelow.
• Classic
DARTsare6‐timeslotDARTsthatsupportupto35MHzcontiguousbandwidth(seeTable3on
page6).
• SingleSuperDARTsare6‐timeslotDARTsthatsu
pporttwonon‐contiguousbandsintheentirefrequency
rangeoftheDART,butcannotexceed39MHztotalRFbandwidth(seeTable4onpage6).
• DualSuperDARTsare12‐timeslotDARTsthatsupport
upto60‐75MHz(seeTable5onpage7)
Table3.
Single‐BayClassicDARTs
DARTModuleType MaximumBandwidth(MHz) NumberofFiberSlots
800APACiD
ENClassic 19 3
800SMRClassic 18 3
850CellClassic 25 4
900SMRClassic 5 1
Table4. Single‐BaySuperDA RTs
(1)
DARTName Usedin… Maximum
Frequency
Span(MHz)
Maximum
Bandwidth
(MH
z)
Maximum
FiberSl
ots
HostUnits HEUs
1800GSMSGLSup
erDART Yes No 75 39 6
1900PCSSGLSu
perDART Yes Yes 70 39 6
2100AWSSG
LSuperDART Yes Yes 45 39 6
2100UMTSSG
LSuperDART Yes No 60 39 6
700IA
BCSGLSuperDART Yes Yes 18 3
700uCSGLSup
erDART Yes Yes 10 2
900EGSMSGLSup
erDART Yes No 35 6
(1) WhenusingaHostUni
twithboththeSeRFIIandSystemBoardIImodules,thebandwidthsandfiberslotsshownareonly
availableinHostUnitDARTSlots1and3forSingle‐BaySuperDARTs.
NOTE: IndustryCanadaPCS20dBnominalbandwidthislessthan61.5MHz.
NOTE: IndustryCanadaAWS20dBnominalbandwidthislessthan47.2MHz