User's Manual

Page6 FlexWavePrismRemoteUnitRFModuleInstallationGuide
©2014 TEConnectivityLtd. TECP77141Issue6 300001744178RevF April2014
RFModuleDARTs
EachRFModulecansupportanyofthefollowingDARTcombinations:
oneClassic
DARToroneSingleSuperDART
twoClassicDARTs(i.e.,t
he6.5W800/900ESMRModule,Non‐Diversity,Classic)
twoClassicDARTs—Diversi
ty
twoSingleSuperDARTs—Diversity
on
eDualSuperDART
on
eortwosetsofTxorRxBoards(HDM).
EachRFModulewillhaveuptotwo6‐timeslotDARTsorone12‐times
lotDARTperRFModule.
TheDARTtypedeterminesthemaximumnumberoflinks,wherether
ecanbeuptoeightClassicDARTsorSingle
SuperDARTsthatsupport39MHzeach,orupto4DualSuperDARTsthatsupportupto75MHzeach.
PrismsupportstheDARTModuletypeslistedbelow.
Classic
DARTsare6‐timeslotDARTsthatsupportupto35MHzcontiguousbandwidth(seeTable3on
page6).
SingleSuperDARTsare6‐timeslotDARTsthatsu
pporttwonon‐contiguousbandsintheentirefrequency
rangeoftheDART,butcannotexceed39MHztotalRFbandwidth(seeTable4onpage6).
DualSuperDARTsare12‐timeslotDARTsthatsupport
upto60‐75MHz(seeTable5onpage7)
Table3.
SingleBayClassicDARTs
DARTModuleType MaximumBandwidth(MHz) NumberofFiberSlots
800APACiD
ENClassic 19 3
800SMRClassic 18 3
850CellClassic 25 4
900SMRClassic 5 1
Table4. SingleBaySuperDA RTs
(1)
DARTName Usedin… Maximum
Frequency
Span(MHz)
Maximum
Bandwidth
(MH
z)
Maximum
FiberSl
ots
HostUnits HEUs
1800GSMSGLSup
erDART Yes No 75 39 6
1900PCSSGLSu
perDART Yes Yes 70 39 6
2100AWSSG
LSuperDART Yes Yes 45 39 6
2100UMTSSG
LSuperDART Yes No 60 39 6
700IA
BCSGLSuperDART Yes Yes 18 3
700uCSGLSup
erDART Yes Yes 10 2
900EGSMSGLSup
erDART Yes No 35 6
(1) WhenusingaHostUni
twithboththeSeRFIIandSystemBoardIImodules,thebandwidthsandfiberslotsshownareonly
availableinHostUnitDARTSlots1and3forSingleBaySuperDARTs.
NOTE: IndustryCanadaPCS20dBnominalbandwidthislessthan61.5MHz.