User's Manual

Page36 FlexWavePrismRemoteUnitRFModuleInstallationGuide
©2014 TEConnectivityLtd. TECP77141Issue6 300001744178RevF April2014
4 Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:
a ConnecttheMODNTX1/RX1cabletotheRFModule.
i ConstraintheMODNTX1/RX1cableofthelowerRFModulebaytoaccompanyingcablesusingatie
wrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii ConnecttheMODNTX1/RX1cabletotheTX1/RX1orN/C,N‐StyleJackoftheupperRFModulebay.
iii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iv Torquecouplingnutto8±1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigher
thannormalVSWRreportedbythesystem.
b ConnecttheMODNTX0/RX0cabletotheRFModule.
i InserttheNStylePlugoftheMODNTX0/RX0cableintotheTX0/RX0NStyleJackofthelowerRF
Module bay. If RF Module connection is not available, constraintheMODNTX0/RX0cableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8±1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigher
thannormalVSWRreportedbythesystem.
c ConnecttheLVDSCablestotheRFModule.
i Ifavailable,connecttheMODNDIVLVDSCabletotheDIVreceptacle ofthelower RFModuleby
insertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,constraintheMODNDIV
LVDSCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoor
fromclosing.
ii ConnecttheMODNDIVLVDSCabletotheDIVreceptacleoftheupperRFModulebyinsertingand
slidinginuntilfullyseated.IfDIVreceptacleisnotavailable,constraintheMODNDIVLVDSCableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
iii Ifavailable,connecttheMODNPRIMLVDSCabletothePRIMreceptacleoftheupperRFModuleby
insertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,constraintheNPRIMLVDS
CabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfrom
closing.
NOTE: FullinsertioncanberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRFModule
Receptacle. This can be verified by lightly pulling back on the LVDS connector while making sure not to
depress the release trigger. When fully inserted, the cable should not be able to be removed from the
receptacle.
d ConnectthePowercabletotheRFModule.
i ConnectthePowerCableConnectortothePWRreceptacleofthelowerRFModulebyinsertingand
slidinginuntilfullyseated.
ii ConnectthePowerCableConnectortothePWRreceptacleoftheupperRFModulebyinsertingand
slidinginuntilfullyseated.IfPWRreceptacleisnotavailable, constrain the Power Cable to
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintotheRFModule
Receptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnectorwhilemakingsurenot
todepressthereleasetriggerson
theendsoftheconnector.Whenfullyinserted,thecableshouldnotbe
abletoberemovedfromthereceptacle.